The Cadence Steam Aging Systems are designed to meet military and commercial Hi-Rel specifications (MIL-STD 202 Method 208 and others) for artificial aging of all electronic components and circuit boards including high density discrete components relays transistors capacitors including SMT and axial components.
Automated system designed to meet military and commercial Hi-Rel specifications (MIL-STD 202 Method 208) for artificial aging of electronic components and circuit boards including high density discrete components.
该自动化系统可以满足军事和商业上高可靠性的要求(标准
MIL-STD 202、方法208等等),可以对高密度零件、分立
封装零件等各种电子零件和线路板进行人工老化试验。
The Cadence Systems come in 2 configurations the standard configuration offers a single steam chamber for large components. The DX features 3 individually timed ESD protected drawers with a unique closure mechanism that reduces steam escapement during drawer removal. All systems provide complete monitoring and control of steam or water temperature and feature automatic timing of the test duration.
Artificial steam aging of components must occur over a very narrow temperature range typically at 93oC +/-3 degrees. The Cadence Steam Aging Systems are the only systems currently on the market that meet this precise control requirement. This thermal accuracy makes the Cadence Systems ideal for component manufacturers and military commercial and industrial end users.