:RETZ/我们一直致力于流体控制和测控领域的持续创新,始于2005……进口锂电池供电电磁流量计原理及用途Principle
and purpose
1.电池供电电磁流量计由传感器和转换器两部分构成。它是基于法拉第电磁感应定律工作的,用来测量电导率大于5μS/cm导电液体的体积流量,是一种测量导电介质体积流量的感应式仪表。除可测量一般导电液体的体积流量外,还可用于测量强酸强碱等强腐蚀液体和泥浆、矿浆、纸浆等均匀的液固两相悬浮液体的体积流量retz The
battery powered electromagnetic flowmeter consists of a sensor and a converter.
It is d on Faraday's law of electromagnetic induction and is used to
measure electrical conductivity greater than 5 μ The volume flow rate of S/cm
conductive liquid is an inductive instrument for measuring the volume flow rate
of conductive media. In addition to measuring the volume flow rate of general
conductive liquids, it can also be used to measure the volume flow rate of
strong corrosive liquids such as strong acids and alkalis, and homogeneous
liquid-solid two-phase suspension liquids such as mud, pulp, and pulp
2.基本原理(如图所示)基于法拉第电磁感应定律:E=K*B*D*V,其中E是感应电动势;K是仪表常数;B是磁感应强度;D是测量管直径;V是平均流速 The basic
principle (as shown in the figure) is d on Faraday's law of electromagnetic
induction: E=K * B * D * V, where E is the induced electromotive force; K is
the meter constant; B is the magnetic induction strength; D is the diameter of
the measuring tube; V is the average flow rate
不能测量非导电介质,如气体,油类,如介质含有大量气体,产生测量严重波动
Unable to measure non-conductive media such as gases and oils, such as media
containing a large amount of gas, resulting in severe fluctuations in
measurement
(2)必须存在磁场 Magnetic field
must be present
励磁电流流经测量管上下励磁线圈产生磁场。励磁线圈断路,流量计不工作,励磁电流稳定性直接影响仪表测量 The
excitation current flows through the upper and lower excitation coils of the
measuring tube to generate a magnetic field. The excitation coil is open
circuit, the flowmeter does not work, and the stability of the excitation
current directly affects the instrument measurement
测量管必须为非导磁材料,保证磁场穿过导管(测量管应采用不锈钢材质) The measuring
tube must be made of non magnetic conductive material to ensure that the magnetic
field passes through the tube (the measuring tube should be made of stainless
steel)
(3)实际测量值为流体流速 The actual
measured value is the fluid flow rate
电磁流量计实际测量介质的流速(它是速度式流量计) Electromagnetic
flowmeter actually measures the flow rate of the medium (it is a velocity type
flowmeter)
:RETZ/我们一直致力于流体控制和测控领域的持续创新,始于2005……进口锂电池供电电磁流量计原理及用途Principle and purpose
1.电池供电电磁流量计由传感器和转换器两部分构成。它是基于法拉第电磁感应定律工作的,用来测量电导率大于5μS/cm导电液体的体积流量,是一种测量导电介质体积流量的感应式仪表。除可测量一般导电液体的体积流量外,还可用于测量强酸强碱等强腐蚀液体和泥浆、矿浆、纸浆等均匀的液固两相悬浮液体的体积流量retz The battery powered electromagnetic flowmeter consists of a sensor and a converter. It isd on Faraday's law of electromagnetic induction and is used to
measure electrical conductivity greater than 5 μ The volume flow rate of S/cm
conductive liquid is an inductive instrument for measuring the volume flow rate
of conductive media. In addition to measuring the volume flow rate of general
conductive liquids, it can also be used to measure the volume flow rate of
strong corrosive liquids such as strong acids and alkalis, and homogeneous
liquid-solid two-phase suspension liquids such as mud, pulp, and pulp
2.基本原理(如图所示)基于法拉第电磁感应定律:E=K*B*D*V,其中E是感应电动势;K是仪表常数;B是磁感应强度;D是测量管直径;V是平均流速 The basic principle (as shown in the figure) isd on Faraday's law of electromagnetic
induction: E=K * B * D * V, where E is the induced electromotive force; K is
the meter constant; B is the magnetic induction strength; D is the diameter of
the measuring tube; V is the average flow rate
(1)只能测量导电介质 Only conductive media can be measured
电导率限制条件6≥1-5uS/cm(水>20uS/cm)(低电导率>0.05uS/cm使用仪表) Conductivity limit condition 6 ≥ 1-5uS/cm (water>20uS/cm) (low conductivity>0.05uS/cm using dedicated instruments)原理及用途.jpg
不能测量非导电介质,如气体,油类,如介质含有大量气体,产生测量严重波动 Unable to measure non-conductive media such as gases and oils, such as media containing a large amount of gas, resulting in severe fluctuations in measurement
(2)必须存在磁场 Magnetic field must be present
励磁电流流经测量管上下励磁线圈产生磁场。励磁线圈断路,流量计不工作,励磁电流稳定性直接影响仪表测量 The excitation current flows through the upper and lower excitation coils of the measuring tube to generate a magnetic field. The excitation coil is open circuit, the flowmeter does not work, and the stability of the excitation current directly affects the instrument measurement
测量管必须为非导磁材料,保证磁场穿过导管(测量管应采用不锈钢材质) The measuring tube must be made of non magnetic conductive material to ensure that the magnetic field passes through the tube (the measuring tube should be made of stainless steel)
(3)实际测量值为流体流速 The actual measured value is the fluid flow rate
电磁流量计实际测量介质的流速(它是速度式流量计) Electromagnetic flowmeter actually measures the flow rate of the medium (it is a velocity type flowmeter)
进口锂电池供电电磁流量计技术参数 Technical parameter
公称通径(mm)
(特殊规格可定制)
管道式:DN10~DN3000
插入式:DN200~DN3000
流动方向:
正,反,净流量
量程比:
150:1
重复性误差:
测量值的±0.1%
精度等级:
管道式:0.5级,1.0级
被测介质温度:
普通橡胶衬里:-20~+60℃
高温橡胶衬里:-20~+90℃
聚四氟乙稀衬里:-30~+100℃
高温型四氟衬里:-20~+180℃
额定工作压力:
(高压可定制)
DN6-DN80:≤1.6MPa
DN100-DN250:≤1.0MPa
DN300-DN1200:≤0.6MPa
流速范围:
0.1-15m/s
电导率范围:
被测流体电导率≥5μs/cm
电流输出:
负载电阻
0~10mA:0~1.5kΩ
4~20mA:0~750 kΩ
数字频率输出:
输出频率上限可在1~5000HZ内设定带光电隔离的晶体管集电极开路双向输出。外接电源≤35V导通时集电极*大电流为250mA
供电电源:
AC220V、DC24V或3.6V电池
要求直管段长度
上游≥5DN,下游≥2DN
连接方式:
流量计与配管之间均采用法兰连接,法兰连接尺寸应符合GB11988的规定
防爆等级:
mdIIBT4
防护等级:
IP65,特殊订制*高可达IP68
环境温度:
-25~+60℃
相对温度:
5%~95%
消耗功率:
小于20W
富林克致力于作为流体控制*,负责地区RETZ产品的营销管理和服务,从而创造价值的企业,RETZ以“坚持更好的品质”为根本,以“持续实现具有创造性、高品质产品和服务的企业价值,为当今社会的繁荣作出贡献”为企业理念