Model 40A (dc to 40 GHz / 2.9mm K connector input) Now available with nickel alloy contacts for probing aluminum pads
High Performance Microwave Probes
Dual Microwave Probe
Features
Two probes on one positioner
Ground to signal spacing from 50 to 2540 microns
Signal to signal spacing is user adjustable
Same performance as individual Model 40A, 50A, 67A, and 110H probes
Patented coaxial design
Differential calibration substrates available for two, three and four port calibrations
The PICOPROBE® DUAL MICROWAVE PROBE consists of two separate probes mounted on a single holder. One probe is fixed to the holder; the other is adjustable. Each probe may be individually configured with GSG, GS, or SG footprints having any fixed pitch from 50 to 2540 microns. The probe to probe (signal to signal) spacing is user adjustable over a 4000 micron (160 mil) range. When ordering, an initial signal to signal spacing should be specified (up to .75 inches).
ORDERING INFORMATION
To order a Dual Probe, use our regular Model 40A literature as a guide to specify each probe individually. Then, the orientation of the two probes is specified from left to right looking from the top with the probe tips facing towards you. For example, a
40A-GSG-150 /40A-SG-150-D-300
is a dual probe. The left probe has a GSG footprint with 150 microns between the grounds and signal. The right probe has a SG footprint with 150 microns between the ground and signal. The spacing between the signal of the left probe and the signal of the right probe is 300 microns.
Microwave probes with frequencies up to 110GHz are available. Choose from either the Model 40A (2.9mm connector), Model 50A (2.4mm connector) Model 67A (1.85mm connector) or the Model 110H (1.0mm connector).
深圳市森东宝代理美国GGB全系列探针
Dual Microwave Probe(双探头差分探针)
购买须知:
1、此款产品起拍量为一个
2、购买前请一定要咨询客服,询问是否有足够的库存,直接拍下付款者概不发货
3、可开发票,详情请咨询客服
如需其他型号高频探针,请点击:
Model 40A (dc to 40 GHz / 2.9mm K connector input)
Model 50A (dc to 50 GHz / 2.4 mm connector input)
Model 67A (dc to 67 GHz / 1.85 mm V connector input)
Model 110H (dc to 110 GHz / 1.0 mm connector input)
Model 40M/50M/67M 低损耗探针(ultra low loss - dc to 40 GHz)
Model 40A (dc to 40 GHz / 2.9mm K connector input) Now available with nickel alloy contacts for probing aluminum pads
High Performance Microwave Probes
Dual Microwave Probe
Features
Two probes on one positioner
Ground to signal spacing from 50 to 2540 microns
Signal to signal spacing is user adjustable
Same performance as individual Model 40A, 50A, 67A, and 110H probes
Patented coaxial design
Differential calibration substrates available for two, three and four port calibrations
The PICOPROBE® DUAL MICROWAVE PROBE consists of two separate probes mounted on a single holder. One probe is fixed to the holder; the other is adjustable. Each probe may be individually configured with GSG, GS, or SG footprints having any fixed pitch from 50 to 2540 microns. The probe to probe (signal to signal) spacing is user adjustable over a 4000 micron (160 mil) range. When ordering, an initial signal to signal spacing should be specified (up to .75 inches).
ORDERING INFORMATION
To order a Dual Probe, use our regular Model 40A literature as a guide to specify each probe individually. Then, the orientation of the two probes is specified from left to right looking from the top with the probe tips facing towards you. For example, a
40A-GSG-150 /40A-SG-150-D-300
is a dual probe. The left probe has a GSG footprint with 150 microns between the grounds and signal. The right probe has a SG footprint with 150 microns between the ground and signal. The spacing between the signal of the left probe and the signal of the right probe is 300 microns.